PLB 157 – Micro Bath Temperature Calibrator

  • -50 ºC to 160º C
  • 45 x 185 mm calibration volume
  • Multi-function including liquid Bath and Dry Block

Description

The PLB 157 is a ultra low Micro Bath with an operating range from -50ºC to 160 ºC, large calibration volume (45 x 185 mm) and unrivaled flexibility.

As a Micro Bath the PLB 157 is suitable for calibrating any type and odd shaped temperature sensors including mechanical bulb thermometer and UTI

Accessories are available to convert the PLB 157 to a traditional dry block temperature calibrator, surface sensors temperature calibrator and even infrared sensors temperature calibrator.

The PLB 157 is available in two versions- the TS and TC.  The TS  has a digital display for set and nominal temperature, the TC additionally includes inputs for reference sensor and test thermometers

Features

  • Large Calibration Volume
  • 4 operating modes
  • Use as Liquid bath
  • Use as Dry Block with optional inserts
  • Use as Surface Temperature calibrator with optional insert
  • Use a Infrared Sensor Calibrator with optional insert
  • Extended features including full programmable auto ramp
  • Dual Inputs for reference and sensor under-test display ( TC version)

Specifications

Temperature Range
@ 20ºC-38C to 160 C
@ 0ºC-50 to 160°C
Stability
As Liquid Bath± 0.01 °C
As Dry block± 0.01 °C
Uniformity as Liquid Bath
Axial± 0.02 °C @ -10 °C
± 0.02 °C@ 0°C
± 0.01 °C @ 120 °C
Radial± 0.01 °C @ -10 °C
± 0.01 °C@ 0°C
± 0.02 °C @ 120 °C
Accuracy
with Internal Sensor± 0.15 °C
with External Sensor SRS (*)± 0.08 °C   ( TC version only)
Display 
Set Point-50 to 160°C
Resolutionuser-selectable 0.1 , 0.01 C
Unitsuser-selectable C, F,K
Calibration Volume
As Liquid Bath44.5 x 185 mm
As dry block45 x 170 mm ( dry inserts optional)
Heating timeambient to 120°C: 25 min ( include time to stability)
Cooling timeambient to -10°C : 25 min (include time to stability)
Thermocouple Input (TC version)
TypeK,J,N,R,S,E,T,B
Range0 to 1300 °C
Accuracy± 1°C Include CJC error
Resolutionuser-selectable 0.1 , 0.01 °C
RTD’S input ( TC version only)
TypePt 100 (3/4 wires)
Range-100 C to 700 °C
Accuracy± 0.3 °C
Resolutionuser-selectable 0.1 , 0.01 °C
General
Computer interfaceRS 232 as standard ( UBS adapter supplied as option) and EIUK software included
Switch TestYes
RampYes fully programmable
Weight10.2 Kg
Dimensions160x3350x365 mm
Power Requirement115 o 230 V – 50/60 Hz
Power300 VA
 Notes* Require SRS sensor and special UKAS matching calibration. Long term drift not included